Test method IEC 62133 4.3.5 / UL 2054 #23
From start temperature of 20degC+/-5deg increase temperature at rate of 5degC +/-2deg / minute to 130degC =/-2deg. Hold for 10 minutes before returning to 20degC +/-5deg.
At end of test record all data from software monitor, including pack voltage, cell voltage, Remain capacity, RCP, counter values, use time, etc.
Measure pack voltage and self discharge current with multi-meter.
Test pack function unit, record charge time and discharge time, check LED functions.
Pass criteria : no fire or explosion