Electrical Characterization : The electrical transport and optical response of the devices were carried out in the chamber of NSOM. The resistance-gate voltage characteristics of devices were measured using standard lock-in techniques. For the optical response of the devices, 325 nm and 445 nm lasers were used as the light source. The measurements of dark current and photocurrent were carried out by Keithley 6430.